VFFS and Flow Wrapper Seal Problems: Causes and Fixes
If you send me a leaking bag, my first question is which seal leaked. Was it the long back seal, or the cross seal at the top or bottom? On the vertical and pillow machines we build, those two seals are made by separate heated parts. So the answer tells us where to look. Then we look at what the bad seal looks like, because each defect points to a different cause.
- Fixing a machine you already run? Start with the table below. If leaks come and go, or started with a new film lot, go to the film check, then the jaw faces.
- Choosing your next machine? Go straight to what to agree before you order.
What Does Your Bad Seal Look Like, and Where Should You Check First?
Find the row that matches your bag. Each row names the seal to look at, the likely cause and the first thing to check. Links in the Check first column jump to the section that covers each check. The last column uses the failure names from our bag sealing methods guide, where each mechanism is explained in more detail.
| What you see | Which seal | Likely cause | Check first | Failure name |
|---|---|---|---|---|
| The seal peels open with little force | Either seal; often the one whose settings or film just changed | Too little heat, pressure or dwell for this film | That seal’s temperature, pressure and dwell, then the real jaw-face temperature | Cold or under-seal |
| Bags pop open in the carton or in transit | Either seal | A seal too weak for handling, or one that peels under load | A peel check on cooled bags, then that seal’s settings | Cold or under-seal, if the seal peels apart |
| The seal looks complete, but the bag still leaks | Either seal; test the crossing point too | A fine channel from a crease or trapped product | Find the leak spot with a dye or bubble check, then look for creases or specks there | Wrinkle or crease leak; product-in-seal capillary leak |
| Powder, specks or liquid inside the seal | Usually the cross seal or end seal | Dust or product on the seal faces when the jaws close | Dust at the fill point, then the jaw faces | Product-in-seal capillary leak |
| Creases or folds running across the seal | Either seal | Film arriving creased, or uneven jaw contact | The film path if the crease is there before the jaws; jaw flatness and alignment if not | Wrinkle or crease leak |
| The seal looks shiny, distorted or burnt, and the edge cracks when flexed | Either seal | Too much heat or dwell for the film | Lower the heat on that seal first, and check the film’s sealing window | Burnt or over-seal |
| A leak right where the back seal meets the cross seal | The crossing point | Extra film layers that the jaws don’t fully seal | The cross-seal jaw faces at that spot, and whether the fin lies flat | Channel leak at the layer step |
| Leaks only now and then, or only since a new roll | Either seal | A change in the film, or wear and residue on the jaw faces | The new roll against the old one, then the jaw faces | Match the bag to the rows above |
| Bags not cut apart, or a ragged cut | The knife in the cross-seal or end-seal jaws | A worn or damaged knife, anvil or counter-knife | The knife edge and the part it cuts against | Not a seal failure |
Two habits make the rest of this guide work. Change one setting at a time and write down what you changed. Keep a few bad bags beside a good one, so you can compare them after each change.
When this guide is not enough
The steps below assume a heat seal on a machine that heats and runs normally. These four cases need a different route.
- The jaws don’t heat, or the controller shows an alarm. That points to an electrical fault in a heater, sensor or controller. Stop the machine and have a qualified electrician or the machine supplier deal with it.
- The leak is not in a seal. A pinhole in the film, a puncture from sharp product or damage in transit won’t respond to seal settings. Find the leak with a bubble or dye check, then look at the film and how packs are handled.
- Sterile medical packs. They are validated under their own rules. Use this guide for the principles only, and take validation questions to your quality or regulatory team.
- Ultrasonic or impulse sealers. They deliver heat and pressure in other ways, so the temperature, pressure and dwell steps here may not carry over. See how the sealing methods differ.
Which Seal Failed: the Back Seal or the Cross Seal?
Each row in the table starts with which seal failed. If you already know, skip to the settings. This section is for anyone who needs to tell the seals apart first.
On a back-seal VFFS machine, distinguish the longitudinal seal from the cross seals. Heated vertical seal bars press the film edges together along the forming tube to make the back seam. On some models, such as the SW-420E, heated rollers do this job instead.
Below them, the cross-seal jaws seal the top of one bag and the bottom of the next in one stroke. A blade inside the jaws cuts the bags apart.
A horizontal flow wrapper, or pillow packing machine, does the same jobs on its side. Heated center-seal rollers make the fin seal along the bag. Rotary or box-motion end-seal jaws seal the front of one pack and the rear of the next, and a knife in the jaws separates them.
So the position of the leak tells you which seal to work on. A leak along the length of the bag points to the back seal or fin seal. A leak across the top or bottom points to the cross seal or end seal. A leak exactly where the two meet has its own section below.
The two seals also have separate heat settings. Our SW-1528 has one temperature controller for the longitudinal seals and another for the cross seals. A laminate such as PET/PE may need a different temperature on each. In our Mexico sachet project, the back seal and the cross seal each had their own adjustable temperature.
Once you know which seal failed, work on that seal’s settings and jaws only. If you change both seals at once, you lose track of which change fixed the problem.
Why Is the Seal Weak or Leaking? Temperature, Pressure and Dwell Time
Once you know which seal failed, the usual question is whether to turn up the heat. Do it only when the bad seals look under-sealed and the measured face temperature matches the setpoint. Even then, stay inside the film’s sealing window. If the bags show product, creases or burn marks, more heat won’t fix them.
A heat seal forms when the film’s inner sealant layer melts and fuses within a band of temperature, pressure and dwell time. With too little of any of the three, the sealant never fully fuses. The seal looks closed but peels open or leaks.
Too much heat or dwell causes the opposite problem. The film thins, distorts or burns through. That band is called the sealing window, and it belongs to the film, not the machine. See how the sealing window works for more detail.
The three settings work together. DuPont’s heat sealing guidelines say a change in one typically requires a change in one or more of the others. More dwell, for example, can let you seal at a lower temperature.
The number on the screen is not always what the film sees. Actual sealing pressure is often different from the setpoint, and a thermocouple measures only one spot on the jaw. It can’t show whether the whole seal face is at the same temperature.
If the seal is weak at one end or on one side only, suspect a cold spot or uneven contact before you raise the setpoint. Hot and cold spots, and warped or misaligned jaws, are on DuPont’s list of factors too.
Timing matters as well. A seal is still soft when hot jaws open, and it reaches full strength only as it cools. Judge a seal once it has cooled, not straight off the jaws.
A seal can also take load while it is still hot. On many vertical machines, product drops into the bag right after the cross-seal jaws open, as Intertek notes in its hot tack summary. It lands on a bottom seal made moments earlier, so the seal’s hot strength, or hot tack, comes into play. If a bottom seal tears as product drops into the bag, its hot strength may be too low for that load. ASTM F1921 measures this hot tack strength in the laboratory. It notes that in form-fill operations, hot seals with too little resistance can break during packaging. Hot tack depends on the sealant, so it is one of the film questions below.
Speed changes the timing too. DuPont describes true dwell as the time the film is actually pressed together, and a cycle time may or may not include jaw travel. If a speed change shortens the time the jaws stay closed, true dwell gets shorter too. DuPont adds that even a fraction of a second’s difference in when the materials reach sealing temperature can measurably change seal strength, so recheck seals after any speed change.
On our vertical and pillow machines, temperature and pressure are set on the HMI for each film. On models such as the SW-420E, dwell time is adjustable too. Start from the sealing window your film supplier gives you.
If the supplier’s window came from a laboratory sealer, keep in mind what that test covers. ASTM F2029 describes how laboratory heat seals are prepared, and production-machine validation is outside its scope. The same goes for temperature ranges published online. They may come from a single film, jaw and speed, often on a laboratory sealer. A jaw setpoint is also not the temperature at the seal itself. Treat any window as a starting point that your machine still has to prove.
Then adjust in this order.
- Match the bad bag to a row in the table above, and deal with any cause that isn’t heat first.
- Check that the real face temperature and pressure match the setpoints. The jaw checks below show how.
- Change one setting at a time, in small steps, and write down each change.
- Let the seals cool before you judge them, and compare them with a good bag.
- Keep the lowest temperature that reliably gives the seal strength you need at your pressure and dwell, as seal parts supplier Vanguard Components advises. Running hotter wears PTFE coatings faster and raises the risk of jaw distortion.
Why Is Powder or Product Caught in the Seal, and Will More Heat Fix It?
Product in the seal is the case where more heat won’t help. On powder lines, it is a common reason why a strong-looking seal still leaks. Particles that land on the seal faces stop the two sealant layers fusing at that spot. They leave a fine channel, even though the seal can still pull strong. This is a product-in-seal capillary leak.
Dust also lands on the hot jaws. On our UK powder zipper pouch line, dust was the main threat to the seal. Powder resting on hot jaws chars and leaves a weak, porous seal.
More heat is not a substitute for keeping product out of the seal. Some sealants tolerate contamination under suitable conditions, but this must be checked with the actual film and product. In our Mexico protein powder sachet case study, we wrote that temperature cannot fix contamination. A dust cloud at the cross-seal jaws can trap particles in the seal area and leave a leaker. Research points the same way. A 2023 review of seal materials reports that, in most cases, contamination lowered seal strength, especially at high contamination densities.
So deal with the dust where it starts, at the fill point. How that is done depends on the machine.
- On the SW-420E, an optional dust collection hood mounts above the filling station.
- On our premade pouch powder machine, the optional dust collector sits at the filling station, away from the sealing stations further round the table. A bag-mouth sweeping device then clears powder from the pouch mouth before sealing.
- For liquids and sauces, keeping product off the seal area also starts at the fill station.
Static on the film can make this worse. Static-control maker Meech notes that charge on the film pulls powder and light dust onto its inner surface and into the seal. Its answer is an ionising bar before the forming tube and another just before the seal jaws.
On the film side, Dow lists sealing through contamination for one of its sealant grades. If your product dusts, add that to the questions for your film supplier.
What Causes Wrinkles, Burn-Through and Film Sticking to the Jaws?
Not every channel comes from product. Creases, burn marks and film sticking to the jaws each start somewhere else, so each has its own first check.
Wrinkles and creases
A crease caught in the seal leaves a channel, often at corners and at zipper or gusset transitions. First work out where the crease starts. If it is already in the film before the jaws close, look upstream at the film path, including the former, film tension and tracking.
If the film arrives flat and the crease appears only in the seal, look at the jaws. Jaw bars must be straight and faces flat to press evenly across the seal. A warped or misaligned jaw gives uneven contact and uneven heat. Adding pressure won’t remove a crease that comes in with the film.
Burn-through, brittle seals and split corners
A shiny, distorted or burnt seal usually means too much heat or dwell for the film. Over-sealing thins and embrittles the film at the seal edge, so it cracks when the bag flexes. Corners that split when the bag is handled can be a sign of this.
Lower the heat on the seal that shows the damage, then check the result after the seal cools. Some mono-material structures have less temperature margin between sealing and distortion. Where the outer layer softens close to the sealant’s sealing range, extra heat can deform the film.
Film sticking to the jaws
If film sticks to a jaw, look at the jaw surface first. If the jaws carry PTFE tape or a non-stick coating, check that layer. Where the non-stick layer is missing or worn, molten film can bond to the metal jaw. Residue on the jaw also creates hot and cold spots, according to PTFE tape supplier GORTEF.
Check the tape daily for discoloration, fraying or lifting edges. Stop and isolate the machine according to its maintenance procedure, and let the jaws cool before cleaning. Use a soft cloth and a cleaner approved for the tape or coating, and keep scrapers away from the PTFE surface. If the seal also looks burnt, the heat is probably higher than this film needs.
Why Do Leaks Keep Appearing Where the Back Seal Crosses the End Seal?
One leak spot needs its own check. On a pillow bag, the back seal runs into the top and bottom seals. At that crossing, the cross-seal jaws must seal through more film than anywhere else along the seal. With a fin seal folded flat, that means four layers of film instead of two.
Packaging researchers call this the T-point, also known as the T-junction, and describe it as the most difficult point to seal. Where the layer count steps up, the sealant has to fill the gap beside the fin. A 2023 review notes that some flow is needed to fill channel leaks at wrinkles, contamination and gusset areas where horizontal and vertical seals cross.
Here is how to check the crossing on the machine.
- Look at the crossing at both ends of a few bags, against the light, and compare them with a good bag.
- Run a dye check on that edge. The ASTM F3039 dye-penetration method shows where a seal edge leaks.
- Check the cross-seal or end-seal jaw faces at the spot where the fin lands, for wear or residue.
- Check that the fin lies flat and folds the same way on every bag.
- Note which side of the fin the leak sits on, and whether it is the same side every time.
The film matters here too. The sealant needs a suitable ability to fill these steps, which the 2023 review and Dow call caulkability. More flow is not automatically better, because excess flow can squeeze sealant out of the seal.
When you run sample seals, check the crossing point on purpose, and write it into your acceptance checks.
Are the Jaw Faces, Wear Parts or the Knife the Problem?
If leaks come and go, look at the jaws. Worn or dirty jaws are a leading cause of intermittent leaks. A clean, flat, evenly heated face keeps a seal consistent across its width. The serration or knurling pattern on the face sets how the jaw grips the film and transfers heat.
Before you touch the jaws or the knife, stop the machine and lock it out under its own isolation procedure. The jaws close with force, stay hot after the power is off and carry a blade.
Jaw faces and alignment
- Look along the full width of each face for scoring, flattened serrations and built-up residue.
- Check that the jaws close evenly with a pressure print. Have trained maintenance staff check jaw contact with pressure-indicating film suited to the test temperature and pressure, using the machine’s approved test procedure. Read the imprint for uneven contact.
- Read the print. An even mark across the full width means even contact. A faint end or a gap points to misalignment, worn parts, residue on the face or low pressure in that area.
- If the screen shows the right setpoint but the seals drift, measure the real face temperature. A drifting thermocouple can leave the display looking normal while the actual temperature is off.
- Use a contact surface thermocouple or thermometer on the jaw face, at several points across its width. Compare the readings with the setpoint and with each other.
- For heater faults, have a qualified electrician check the element resistance with a calibrated multimeter. After an element is replaced, recalibrate the controller against a reference thermocouple before production.
- An infrared thermal camera, if you have one, can also show hot spots across the heater surface.
- On a flow wrapper, give the center-seal rollers the same check for residue and wear.
Wear parts
Our SW-1528 page lists sealing strips, heating elements and cutting blades as consumable wear parts. Ask your supplier for the same list for your machine, and keep spares on the shelf. Set the cleaning routine around your own film and product.
The knife
On VFFS and pillow machines, the knife sits in the cross-seal or end-seal jaws. Bags that stay joined, tear instead of cutting, or show a ragged edge point to the knife. Check the edge and the part it cuts against. On flow wrappers, that part is usually a matching knife or an anvil.
The knife cuts cleanly only when its gap and alignment against the anvil or counter-knife are right. Shims under the knife are used to set that fit. Greener, which supplies knives and service for flow wrappers and baggers, says excessive shimming causes cutting problems and can create sealing troubles. So if a new knife needs more and more shim before it cuts, treat that as a warning sign. Look at wear on the knife and anvil, and at how firmly the knife is seated, before adding more.
Check blade sharpness and cut quality regularly to decide when to replace or regrind the knife. Keep one exception in mind. On machines such as the SW-1528, linked-bag output is an option, so joined bags may be intended.
Our page on pillow flow wrap machines with center-seal rollers and end-seal jaws shows how each station works.
Is It the Film? Test a New Roll Before Changing Settings
If the jaws and settings check out, turn to the film. If the problem started with a new roll, a new batch or a new film supplier, suspect the film before the machine. Film compatibility depends on the specific composition, not just the general material category. DuPont also lists variation in material thickness among the factors that affect a seal.
Before you change settings, run a few sample seals with the new roll and the old one on the same settings. Keep part of the last good roll for this comparison. If only the new roll fails, take the result to the film supplier.
Ask the film supplier for these details.
- The film structure and the sealant layer
- The film thickness and its tolerance
- The sealing window for that exact film
- Whether the sealant is designed to seal through dust or product, if you pack a powder
- How the sealant fills fin-seal crossings
- The sealant’s hot tack, if product drops onto a fresh bottom seal
For a mono-material film, check the window for that exact structure rather than reusing settings from a laminate.
If you are ordering one of our machines, send us your film and product. We can run sample seals before shipment, so the window is proven on a trial rather than found at your plant. If you already run one of our machines, send the details in the checklist below, and we can advise on settings and parts.
How Do You Confirm the Seal Is Fixed?
Whatever you changed, test the result before the line runs on. A seal that looks good can still leak, so confirm the fix with checks, not just a glance. Strength and leaks are separate questions. Strength is the force needed to pull the seal apart. Integrity is whether the seal has any leak path, however small.
What to look at
- Both seals and both ends of the bag, across the full seal width
- The crossing point where the back seal meets the cross seal
- Specks of product, creases, channels, and shiny or distorted edges
- A good bag from the same roll, side by side with the repaired one
- The first bags after a restart, a film change or a speed change
- Bags taken again later in steady running, not only at start-up
Simple checks you can run on the line
- Peel by hand (a tug test). Pull a cooled seal apart. Compare it with an acceptable sample made from the same film. If it opens unusually easily, recheck the sealing conditions and inspect for contamination or film damage. Hand peeling is a screening check, not a measured seal-strength result.
- Bubble check. ASTM D3078 puts a pack with headspace under liquid in a vacuum chamber and watches for bubbles. It finds gross leaks, and small leaks may not show. ASTM F2096 pressurizes the pack from inside instead, though its sensitivity has not been evaluated for nonporous packaging.
- Dye check. ASTM F3039 applies a dye penetrant to the seal edge and shows where it leaks. It locates a leak but does not measure its size.
Most of these checks destroy the sample, so use bags taken from the run. After any fix, retest with the same method you used to find the problem, so the results before and after can be compared. Record the settings, film lot and speed that passed, so the next change starts from a known point.
When you need formal tests
Move to formal, recorded tests when you accept a new machine, approve a new film, compare suppliers or need figures for a customer. Specify at least one strength test and one leak test that suit your pack.
ASTM F88/F88M measures the force needed to separate a seal test strip. On its own it does not show that the whole pack is leak-free. ASTM F2054/F2054M pressurizes a pack held between plates to find its weakest point. ASTM F1140/F1140M covers unrestrained burst and creep tests, and states that its results don’t necessarily correlate with F88 seal strength.
There is no publicly established pass number for seals in packaging-machine acceptance testing. Agree the test method and the threshold for your own film and product, and keep sample bags from the run. Visual, peel and leak checks can support routine process control. Select the methods, sampling frequency and acceptance limits for the product and package.
For what each standard measures and where it stops, see the seal test section of our sachet vs stick pack guide. Then check which test finds which defect.
What Should You Agree on the Next Machine Before You Order?
If you are buying your next machine, much of this can be agreed before it ships. If seals are the main risk for your product, put these points in writing before you order.
- How each seal is heated and controlled, and whether its temperature, pressure and dwell can be set separately
- The seal layout and jaw faces for your bag, confirmed by your own engineer
- Dust control at the fill point, if your product dusts
- Sample seals with your own film and product before shipment
- A seal test method and threshold in the factory acceptance test, as our factory acceptance test guide explains
- The wear parts list and the spares that ship with the machine
Here is how that worked on one order. An Irish buyer of ours put it in one line: “I will be packing various powder blends so the important thing is a good seal”.
On that project, the seal was agreed before the order. The SW-L200 seals each pouch twice. We proposed strips on the first seal and a flat face on the second. The buyer’s engineer confirmed that set-up, and the order followed. When the Ireland powder blend case study was written, there was no seal result yet on the buyer’s own pouches.
If you are still choosing a machine type, choose it by how the bag is sealed. Our back-seal vertical packing machines form the film around a tube and make longitudinal and cross seals. Our pillow packing machines wrap the product and make a fin seal and end seals. A premade pouch machine seals a finished bag, often in two passes with the temperature controlled per station.
Frequently Asked Questions
What causes a VFFS seal to leak?
The usual causes are heat, pressure and dwell time that don’t suit the film, dirty or worn seal faces, and product caught in the seal. First find out whether the back seal or the cross seal leaks. Then check that seal’s settings, its jaw faces and the dust at the fill point.
What seal temperature should I set on a VFFS machine?
There isn’t one number that fits every film. Published ranges may come from a single film, jaw and speed, often on a laboratory sealer, and the jaw setting is not the temperature at the seal. The sealing window belongs to the film, so ask your film supplier for it. Start inside that window, run sample seals on the actual roll and adjust in small steps. Look at temperature, pressure and dwell time together. Aim for the lowest temperature that reliably gives the seal strength you need at your machine’s pressure and dwell.
Will a higher temperature fix powder in the seal?
More heat is not a substitute for keeping powder out of the seal. Powder on the seal faces leaves a fine channel, and powder on hot jaws can char into a weak, porous seal. Control the dust at the fill point first. Some sealants tolerate contamination under suitable conditions, and ultrasonic sealing can seal through light contamination in some cases. Only a trial with your actual film and product shows whether either works.
How do I troubleshoot a flow wrapper end seal?
First decide whether the fault is in the fin seal made by the center-seal rollers or in the end seal. For an end-seal leak, check that the jaw faces are clean and not worn. If packs don’t separate, check the knife and the anvil or counter-knife it cuts against. Check the point where the fin crosses the end seal separately.
Is seal strength the same as seal integrity?
No. Seal strength is the force needed to pull the seal apart. Seal integrity is whether the pack has any leak path at all. A seal can be strong and still leak through a fine channel, so test both after a fix.
Not Sure Where Your Seal Problem Starts?
These details help us see which seal failed and why.
Please Send
- Photos of the bad bag, front and back, plus a close-up of the failed seal
- Which seal fails: the back seal, a cross seal or the crossing point
- How often it happens: every bag, now and then, or after a roll change
- The film structure and thickness, and the supplier’s sealing window if you have it
- The product, and the bag width and length
- Your current temperature, pressure, dwell time and machine speed
- The machine type and model
- If you are planning a new machine, a sample of the film and product
Related Guides and Factory Information
- Vertical Packing Machines
- Pillow Packing Machines
- Bag Sealing Methods Compared
- Sachet vs Stick Pack vs Packet
- Packaging Machine Factory Acceptance Test Guide
- SW-1528 Four-Side Seal Packing Machine
- SW-420E Auger Powder Packing Machine
- SW-350A Pillow Packing Machine
- Mexico Protein Powder Sachet Case Study
- Ireland Powder Blend Zipper Pouch Case Study
- Visit the Factory Page
- VFFS Film Tracking Troubleshooting: Film Drift, Missed Eye Marks and Inconsistent Bag Length
- More from the blog
References and Sources
- DuPont: Heat Sealing Guidelines: how time, temperature and pressure interact, and why actual pressure can differ from the setpoint; written for sterile medical packaging, used here for the principle
- TOSS Heat Seal: Process Control Improves Heat Seal Quality: why the bond forms on cooling, what a thermocouple can measure, and why jaw bars must be straight
- Vanguard Components: Heat Sealing Machine Maintenance: thermocouple drift behind a normal-looking display, heater element checks, and setting the lowest effective sealing temperature
- GORTEF: Heat Seal Tape for Food Packaging: film sticking to jaws, residue, and how to inspect and clean PTFE tape
- EDGE Industrial Technologies: FFS Packaging Knives: knife and anvil pairs, and when to replace or regrind a knife
- Greener Corporation: Adjusting Knives, Causes and Solutions for Excessive Shimming: why too many shims under a knife lead to cutting and sealing problems on flow wrappers and rotary vertical baggers; its shim values apply to its own parts and are not used here
- Fujifilm: Prescale for High Temperature, news release (April 2026): what a pressure-film print across the seal face shows, such as uneven alignment, worn parts and residue
- Meech: Bag Sealing Problems in Vertical Form Fill and Seal Machines: how static on the film draws powder into the seal, and where ionising bars are placed
- Dow: AFFINITY HT1285G Polyolefin Plastomer: an example of a sealant resin described for sealing through contamination and for caulkability
- Bamps, Buntinx and Peeters (2023), Seal materials in flexible plastic food packaging: a review, Packaging Technology and Science: contamination and seal strength, and channel leaks where horizontal and vertical seals cross
- Delle Cese, Saha, Roy and Singh (2017), Journal of Applied Packaging Research: the T-point where the fin seal meets the end seal
- ASTM F88/F88M: seal-strength testing; 2023 edition
- ASTM F2054/F2054M: restrained-plate burst testing; 2013 standard reapproved in 2024
- ASTM F1140/F1140M: unrestrained burst and creep testing; 2013 standard reapproved in 2025
- ASTM F2029: laboratory heat-seal preparation; 2016 standard reapproved in 2021
- ASTM F1921/F1921M: hot seal strength (hot tack), measured in the laboratory before the seal cools; 2012 standard reapproved in 2023
- Intertek: Hot Seal Strength ASTM F1921: a test-lab summary of hot tack, and why it matters when product drops into the bag right after the horizontal seal bars open
- ASTM F2096: gross leaks by internal pressurization; 2011 standard reapproved in 2019
- ASTM D3078: gross leaks by bubble emission in a vacuum chamber; 2002 standard reapproved in 2021
- ASTM F3039: dye-penetration leak detection in nonporous packaging; 2023 edition
Public-data note: ShengWei product pages, case studies and the reference pages above were checked between 27 and 31 October 2026. ASTM links lead to public standard summaries; full test procedures may require access to the standards. This article gives no temperature, pressure or dwell values, because the sealing window depends on your film. Apart from the published case studies linked above, it does not report any customer’s bag dimensions, output or machine configuration.
Send Your Bag Photos
Send the photos and the details in the checklist above. We’ll tell you which seal to look at first and which checks to run. For a ShengWei machine, we can also advise on specific settings and parts. If you are planning a new machine, we’ll reply with a suitable configuration and a quotation.
Email info@shengweimachine.com · or contact our engineering team
International Sales Manager · ShengWei Machine